Product Details
Product description

PT-FIT 35/220-240S

PT-FIT 70/220-240S

Applications
Suitable f. fixtures with prot. class Class I | Class II
Dimming range -
Dimmable No
ECG reset time > 0.5 s
Overload protection Yes
Overtemperature protection Automatic switch off, reversible by mains reset
Restriction on ignition time 20 min
Certificates & Standards
Approval marks – approval VDE | VDE-EMC
EEI – Energy Label A2
Standards acc. to EN 61347-2-12 | acc. to EN 55015:2006 + A1:2007 | acc. to EN 61000-3-2 | acc. to EN 61547
Type of protection IP20
General Description
Design / version Built-in unit
New article NEW
Logistical Data
Product weight 250 g
Relative humidity 5…85 % 1)
Temperature range at storage -40…85 °C
Technical – Electrical Data
Nominal wattage + Power loss 0
Inrush current 30 A 45 A
Rated power factor λ 0.95 2)
Maximum mains current 0.20 A 0.36 A
Nominal voltage 220-240 V
Mains frequency 50…60 Hz
DC voltage -
Lamp wattage 39 W 73 W
Operating frequency 0.165 kHz
Output voltage 250 V
Ignition voltage 4.5 kVp
Device power loss 4.5 W

7.0 W 3)

Max. no. of ECGs on circuit breaker 10 A 15 7
Max. no. of ECGs on circuit breaker 16 A 26 13
Maximum cable capacity ECG/lamp 120 pF
TH full width at half maximum 150 µs 250 µs
Type of current AC
Technical – Geometries
Cable cross-section, output side 0.5…1.5 mm²
Cable cross-section, input side 0.5…1.5 mm²
Maximum cable length – system 1.5 m
Length 110.00 mm
Width 75.00 mm
Height 30.00 mm 32.00 mm
Mounting hole spacing, length 99 mm
Mounting hole spacing, width 64 mm
Wire preparation length, input side 8.5…9.5 mm
Wire preparation length, output side 8.5…9.5 mm
Technical – Temperatures
Ambient temperature range -15…+55 °C
Operating temperature 85 °C
Max. housing temperature in case of faul 110 °C

General

  • Supply voltage: 220 V–10 %/240 V+10 %
  • Line frequency: 50–60 Hz
  • Not suitable for dc operation
  • RI suppression: to EN 55015 (A1: 2007) up to 300 MHz
  • Safety: to EN 61347-2-12
  • Line harmonics: to EN 61000-3-2
  • Immunity: to EN 61547
  • Luminous flux factor 1 compared with CCG operation
  • Instant hot restart not possible
  • VDE Sign EMV Sign